If you are unable to take anticoagulants a special metal filter can protect you from a pulmonary embolism. This device is called a vena cava filter. The vena cava is a large vein in your abdomen. It carries blood back to your heart and lungs. Your vascular surgeon may recommend a vena cava filter if you are not a candidate for drug therapy for DVT or if drugs didn’t reduce your clots. Vena cava filters trap the clots that break away from your leg veins before they can reach your lungs. Usually, your vascular surgeon inserts the filter into your vena cava through a catheter placed into a leg, neck or arm vein.
In an inferior vena cava filter placement procedure, interventional radiologists use image guidance to place a filter in the inferior vena cava (IVC), the large vein in the abdomen that returns blood from the lower body to the heart.
Blood clots that develop in the veins of the leg or pelvis, a condition called deep vein thrombosis (DVT), occasionally break up and large pieces of the clot can travel to the lungs. An IVC filter traps large clot fragments and prevents them from traveling through the vena cava vein to the heart and lungs, where they could cause severe complications or even death.
Until recently, IVC filters were available only as permanently implanted devices. Newer filters, called optionally retrievable filters, may be left in place permanently or have the option to potentially be removed from the blood vessel later. This removal may be performed when the risk of clot travelling to the lung has passed. Removal of an IVC filter eliminates any long term risks of having the filter in place. It does not address the cause of the deep vein thrombosis or coagulation. Your referring physician will determine if blood thinners are still necessary. However, not all retrievable IVC filters are able to be retrieved. These filters can be safely left in place as permanent filters.
Inferior vena cava (IVC) filters are placed in patients who have a history of or are at risk of developing blood clots in the legs, including patients:
IVC filters are used when patients cannot be successfully treated by other methods, including blood thinning agents.
Prior to your procedure, your blood may be tested to determine how well your kidneys are functioning and whether your blood clots normally.
You should report to your doctor all medications that you are taking, including herbal supplements, and if you have any allergies, especially to local anesthetic medications, general anesthesia or to contrast materials containing iodine (sometimes referred to as “dye” or “x-ray dye”). Your physician may advise you to stop taking aspirin, nonsteroidal anti-inflammatory drugs (NSAIDs) or blood thinners for a specified period of time before your procedure.
Also inform your doctor about recent illnesses or other medical conditions.
Women should always inform their physician and x-ray technologist if there is any possibility that they are pregnant. Many imaging tests are not performed during pregnancy so as not to expose the fetus to radiation. If an x-ray is necessary, precautions will be taken to minimize radiation exposure to the baby. See the Safety page for more information about pregnancy and x-rays.
You should eat a light meal the night before your procedure.
You will likely be instructed not to eat or drink anything after midnight before your procedure. Your doctor will tell you which medications you may take in the morning.
You may be allowed to drink clear liquids on the day of your procedure.
If you are diabetic and take insulin, you should receive instructions on eating and insulin dose from the interventional radiologist, as your usual insulin dose may need to be adjusted on the day of the procedure.
You may be asked to remove some or all of your clothes and to wear a gown during the exam. You may also be asked to remove jewelry, eye glasses and any metal objects or clothing that might interfere with the x-ray images.
You should plan to have a relative or friend drive you home after your procedure.
In this procedure, a catheter, iodine contrast (x-ray dye), x-ray or ultrasound equipment for imaging guidance and an inferior vena cava (IVC) filter may be used.
A catheter is a long, thin plastic tube that is considerably smaller than a “pencil lead”, or approximately 1/8 inch in diameter.
The equipment typically used for this examination consists of a radiographic table, one or two x-ray tubes and a television-like monitor that is located in the examining room. Fluoroscopy, which converts x-rays into video images, is used to watch and guide progress of the procedure. The video is produced by the x-ray machine and a detector that is suspended over a table on which the patient lies.
Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a transducer that is used to do the scanning. The transducer is a small hand-held device that resembles a microphone, attached to the scanner by a cord. The transducer sends out inaudible high frequency sound waves into the body and then listens for the returning echoes from the tissues in the body. The principles are similar to sonar used by boats and submarines.
The ultrasound image is immediately visible on a video display screen that looks like a computer or television monitor. The image is created based on the amplitude (loudness), frequency (pitch) and time it takes for the ultrasound signal to return from the area of the patient being examined to the transducer (the device used to examine the patient), as well as the type of body structure and composition of body tissue through which the sound travels. A small amount of gel is put on the skin to allow the sound waves to travel back and forth from the transducer.
Other equipment that may be used during the procedure includes an intravenous line (IV), ultrasound machine and devices that monitor your heart beat and blood pressure.
Using image guidance, a catheter is inserted through the skin into a large vein in the neck or groin and advanced to the inferior vena cava in the abdomen. The IVC filter is then placed through the catheter and into the vein. Once it is in the correct position, the interventional radiologist will release the filter, allowing it to fully expand and attach itself to the walls of the blood vessel.
To remove an IVC filter, a special catheter is inserted into a large vein in the neck or groin and advanced to the site of the filter in the vena cava. A removable IVC filter has a small hook or knob at one end that enables the catheter to capture the filter, close it, pull it into the catheter and then withdraw it from the body.
Image-guided, minimally invasive procedures such as inferior vena cava filter placement and removal are most often performed by a specially trained interventional radiologist in an interventional radiology suite or occasionally in the operating room.
This procedure is often done on an outpatient basis. However, some patients may require admission following the procedure. Please consult with your physician as to whether or not you will be admitted.
You will be positioned on your back.
You may be connected to monitors that track your heart rate, blood pressure and pulse during the procedure.
A nurse or technologist will insert an intravenous (IV) line into a vein in your hand or arm so that sedative medication can be given intravenously. Moderate sedation may be used. As an alternative, you may receive general anesthesia.
The area of your body where the catheter is to be inserted will be shaved, sterilized and covered with a surgical drape.
Your physician will numb the area with a local anesthetic.
A very small skin incision is made at the site.
Using image-guidance, a catheter (a long, thin, hollow plastic tube) is inserted through the skin to the treatment site.
Contrast material may be injected into the inferior vena cava to help guide the catheter and verify precise placement of the IVC filter in the blood vessel.
At the end of the procedure, the catheter will be removed and pressure will be applied to stop any bleeding. The opening in the skin is then covered with a dressing. No sutures are needed.
Your intravenous line will be removed.
The procedure is usually completed within one hour.
Devices to monitor your heart rate and blood pressure will be attached to your body.
You will feel a slight pin prick when the needle is inserted into your vein for the intravenous line (IV) and when the local anesthetic is injected. The arteries have no sensation. Most of the sensation is at the skin incision site which is numbed using local anesthetic.
If the case is done with sedation, the intravenous (IV) sedative will make you feel relaxed and sleepy. You may or may not remain awake, depending on how deeply you are sedated.
You may feel slight pressure when the catheter is inserted, but no serious discomfort.
As the contrast material passes through your body, you may get a warm feeling.
You will remain in the recovery room until you are completely awake and ready to return home.
If your IVC filter was inserted through a vein in your neck, you should be able to resume your normal activities within 24 hours. If your filter was inserted through a vein in your groin, you should avoid driving for 24 hours and lifting heavy objects and climbing stairs for 48 hours. Your physician may provide additional post-procedure instructions.
The interventional radiologist can advise you as to whether the procedure was a technical success when it is completed.
Your interventional radiologist may recommend a follow-up visit after your procedure or treatment is complete.
The visit may include a physical check-up, imaging procedure(s) and blood or other lab tests. During your follow-up visit, you may discuss with your doctor any changes or side effects you have experienced since your procedure or treatment.